Ridge or Peak Trim

Ridge or Peak Trim Ridge Flashing - Floating Note:   Use without ventilator   Part # DIM "A" Length Girth Roof Slope Weight Each FL-200 3 1/2" 10'-2" 15 1/2" 1/4-2 1/2:12 10.22# FL-202 4 1/2" 10'-2" 17 1/2" 2 9/16-

Ridge or Peak Trim

BAT RIDGE FLASHING (NEW)
Ridge Flashing - Floating

Note:

  • Use without ventilator
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-200 3 1/2" 10'-2" 15 1/2" 1/4-2 1/2:12 10.22#
FL-202 4 1/2" 10'-2" 17 1/2" 2 9/16-4:12 12.00#
FL-213 6 1/2" 10'-2" 21 1/2" 1/4-2 1/2:12 14.74#
FL-214 7 1/2" 10'-2" 23 1/2" 2 9/16-4:12 15.49#
BAT RIDGE FLASHING (NEW)
Ridge Flashing - Floating

Note:

  • Use with HW-702 9" Continuous Ventilator only
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-205 10 1/4" 10'-2" 29" 1/4-2 1/2:12 19.12#
FL-207 11" 10'-2" 30 1/2" 2 9/16-4:12 20.11#
BAT RIDGE FLASHING (NEW)
Ridge Flashing - Floating

Note:

  • Use without ventilator
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-200 3 1/2" 10'-2" 15 1/2" 1/4-2 1/2:12 10.22#
FL-202 4 1/2" 10'-2" 17 1/2" 2 9/16-4:12 12.00#
FL-213 6 1/2" 10'-2" 21 1/2" 1/4-2 1/2:12 14.74#
FL-214 7 1/2" 10'-2" 23 1/2" 2 9/16-4:12 15.49#
MBCI Trim RIDGE_HIP FLASHING, FIXED_jpg
Ridge/Hip Flashing - Fixed

Note:

  • Specify roof slope 
  • Use with BattenLok HS and SuperLok only 
  • Use without vent material 
  • Specify use as ridge or hip
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-209 6" 10'-2" 13" 1/2-3 3/4:12 8.91#
FL-211 7" 10'-2" 15" 3 13/16-6:12 10.28#
FL-212 11 1/2" 10'-2" 24" 1/2-3 3/4:12 15.88#
MBCI Trim BAT RIDGE FLASH VENT_jpg
Ridge Flashing

Note:

  • Specify roof slope 
  • Use with FL-254 Perforated Vent Drip
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-300 4 1/2" 10'-2" 19 1/2" 1/2-3 3/4:12 13.37#
FL-302 5 1/2" 10'-2" 21 1/2" 3 13/16-6:12 14.18#
FL-303 7 1/2" 10'-2" 25 1/2" 1/2-3 3/4:12 18.37#
FL-304 8 1/2" 10'-2" 27 1/2" 3 13/16-6:12 19.74#
MBCI Trim RIDGE FLASH VENT METAL_jpg
Ridge Flashing For Metal Vent

Note:

  • Specify roof slope 
  • Use with BattenLok HS and SuperLok only 
  • Use with HW-525 Metal Vent Material
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-540 5 1/2" 10'-2" 22 1/4" 1/2-3:12 14.67#
FL-541 6" 10'-2" 23 1/4" 3 1/16-5:12 15.64#
FL-543 8 1/2" 10'-2" 28 1/4" 1/2-3:12 18.94#
FL-544 9" 10'-2" 29 1/4" 3 1/16-5:12 19.67#
MBCI Trim RIDGE FLASH METALVENT FIXED
Ridge Flash Metal Vent - Fixed

Note:

  • Specify roof slope 
  • Use with BattenLok HS and SuperLok only 
  • Use with HW-525 metal vent material
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-545 8 7/8" 10'-2" 21 1/2" 1/2-3:12 14.74#
FL-546 9 1/2" 10'-2" 22 3/4" 3 1/16-5:12 16.37#
FL-547 11 7/8" 10'-2" 27 1/2" 1/2-3:12 18.85#
FL-548 12 1/2" 10'-2" 28 3/4" 3 1/16-5:12 19.42#
MBCI Trim BattenLokHSRidgeChannel_jpg
BattenLok® HS - Alternate Ridge Channel

Note: 

18 gauge material

Part # Length Girth Weight Each
FL-648 10'-0"` 7 1/4" 12.02#
MBCI Trim BattenLokHSSLXRidgeTrim_jpg
BattenLok® HS - Alternate SLX Ridge Trim

Note:

  • Specify roof slope
Part # DIM "A" Length Girth Roof Slope Weight Each
FL-646 7 3/8" 10'-2" 20" 1/2-1:12 13.19#
FL-646A 7 5/8" 10'-2" 20 1/2" 1 1/16-2:12 13.52#
FL-646B 8" 10'-2" 21 1/4" 2 1/16-3:12 14.01#
FL-646C 8 1/4" 10'-2" 21 3/4" 3 1/16-4:12 14.34#