MBCI Logo  
  BLOG
 
COLOR CHARTS | PRODUCT CATALOGS | ORDER PRODUCTS | ASK AN EXPERT | ARCHITECTS | CONTRACTORS | DEVELOPER | COMMERCIAL BUILDING OWNERS | RESIDENTIAL  
  OUR COMPANY PRODUCTS RETROFIT SOLUTIONS INSULATED METAL PANELS PROJECTS GREEN METAL INSTITUTE RESOURCE CENTER CONTACTS  
   
   
MBCI PRODUCTS

MBCI’s wide array of products is the most extensive in the industry. We offer single skin panels, insulated metal panels, retrofit solutions and much more.

 
     

PBR

The PBR panel is commonly used for a wide variety of architectural, agricultural, commercial and industrial applications. PBR is a structural panel and an exposed fastener panel that can be used for both roof and wall applications. The minimum roof slope for PBR is ½:12.

PBR Product Information
  • Coverage Width – 36”
  • Rib Spacing – 12” on center
  • Rib Height – 1-1/4”
  • Minimum Slope – ½:12
  • Panel Attachment – Exposed Fastening System
  • Gauge – 26 (Standard); 29, 24, 22 (Optional)
  • Finishes – Smooth (standard); Embossed (optional)
  • Coatings – Galvalume Plus®, Signature® 200, Signature® 300
-----------------------------------------------------------------------------------------------------------------------------------------------------
Panel Profiles
 
-----------------------------------------------------------------------------------------------------------------------------------------------------
Additional Information
 
       
CAD Details Product Catalog Installation Manual Color Charts        
CSI Specs        
Warranties Photo Gallery Information Request CSI Specifications        
  -------------------------------------------------------------------------------------------------------------------------------------------------
Engineering Information
  Panel Section Properties: 36"
  -------------------------------------------------------------------------------------------------------------------------------------------------
Code Compliance
 

ASTM E 1646 and 1680 – Air & Water Testing

  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 580 Construction Numbers
  Over Purlins & Joists
  Construction No. 104 Minimum 26 gauge panles. 16 gauge purlins spaced at 63 3/16". 2 1/4" Thick rigid insulation is available.
  Construction No. 112 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 1/4". 2 1/4" Thick rigid insulation is available.
  Construction No. 161 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 3/16". 6" Thick vinyl insulation is available.
  Construction No. 167 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 3/16". 6" Thick insulation and light transmitting panels are available.
  Construction No. 184 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 3/16". 4" Thick insulation and light transmitting panels are available.
  Construction No. 30 Minimum 26 gauge panels. 14 gauge purlins spaced at 60 3/16". 4" Thick insulation is available.
  Construction No. 54 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 3/16". 4" Thick insulation is available.
  Construction No. 542 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 3/16". 6" blanket insulation and light transmitting panels are available.
  Construction No. 79 Minimum 26 gauge panels. 16 gauge purlins spaced at 60 3/16". 4" Thick insulation is available.
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 790 - External Fire
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 263 Internal Fire
  Roof Assemblies Wall Assemblies
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 2218 - Impact Resistance
  -------------------------------------------------------------------------------------------------------------------------------------------------
  FM 4471 - Approval Standard for Class 1 Panel Roofs
  -------------------------------------------------------------------------------------------------------------------------------------------------
  Dade County Approvals
  NOA# 08-0212.06 NOA#07-0717.06
  -------------------------------------------------------------------------------------------------------------------------------------------------
  Florida Approvals
  FL 11868.1 PBR Roof Panel over open framing
  Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +n/a/-142.5
Other: See Attached Section Properties and Allowable Load Table. The panel is a through fastened structural roof panel installed over open framing in accordance with the specified load tables. Limitations Non-HVHZ. Roof panels must be installed per manufacturer erection details.
Installation Instructions
FL11868_R1_II_PBR Roof Manual.pdf

Evaluation Reports
FL11868_R1_AE_PBR Roof PER.pdf


     
  FL 11917.4   PBR Wall Panel over open framing
  Limits of Use
  Approved for use in HVHZ: No
  Approved for use outside HVHZ: Yes
  Impact Resistant: N/A
  Design Pressure: +150.00/-142.50
  Other: 29 ga. -55 psf/+60 psf @ 4'-0" o.c., 26 ga. -90 psf/+80 psf @ 4'-0" o.c, 24 ga. -90 psf/+100 psf @ 4'-0" o.c., 22 ga. -142.5 psf/+150 psf @ 4'-0" o.c. The panel is a thru fastened fastener wall system installed over open framing in accordance with the specified section properties and allowable load tables. Limitations Non-HVHZ. Wall panels must be installed per manufacturer erection details.
Installation Instructions
FL11917_R1_II_PBR wall manual.pdf
 
Evaluation Reports
FL11917_R1_AE_PBR Wall PER.pdf
 
   
 
  TERMS | PRIVACY | CAREERS | SITE MAP | 877.713.6224