LokSeam® is a snap-together SSR system for use on roofs with a minimum slope of 3:12. Panels can be installed over open framing or a solid substructure and are capable of transitioning from roof to fascia with the use of a rib cover. |
| |
|
| Coverage Width – 12” |
| Minimum Slope – 3:12 |
| Panel Attachment – Concealed Fastening System |
| Panel Substrate – Galvalume® |
| Gauge – Standard: 24 Optional: 22 (18”, 16”, 12”) 26 (12” only) |
| Finishes – Standard: Striated Optional: Embossed Striated |
| Coatings – Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic |
| |
|
| CAD Details |
| Product Catalog (PDF) |
| Design/Technical Information Manual |
| Photo Gallery |
| Color Charts |
| Warranties |
| Literature Request |
| Panel Section Properties |
| |
LokSeam® 12" Panel |
| Product Bulletins |
| Technical Bulletins |
| |
LokSeam® - Air & Water Test |
| WindLoad Tables |
| |
12" LokSeam® 22 Ga. - Customer Chart |
| |
12" LokSeam® 24 Ga. - Customer Chart |
| CSI Guide Specifications |
| |
LokSeam® Specifications |
| UL Construction Numbers and (other Code Compliances) |
| |
Over Metal deck w/ Rigid Insulation |
| |
Construction 448 |
Minimum 24 gauge panels, 18" maximum width. Rigid insulation, plywood or OSB and gypsom board are available. 22 gauge metal deck is required. |
| |
Construction No. 303 |
Minimum 24 gauge panels, 18" maximum width. Rigid insulation, OSB and gypsum board are available. 22 gauge metal deck is required. |
| |
Construction No. 342 |
Minimum 24 gauge panels, 18" maximum width. "Loadmaster" mineral board and a metal deck are required. |
| |
Construction No. 486 |
Minimum 24 gauge panels, 18" maximum width. "Loadmaster" mineral board and a metal deck are required. |
| |
Construction No. 508A |
Minimum 24 gauge panels, 18" maximum width. 22 gauge metal deck and nailable insulation are required. Gypsum board is optional. |
| |
Over Purlins & Joists |
| |
Construction No. 254 |
Minimum 24 gauge panels, 18" maximum width. 16 gauge purlins spaced 48" on center for 24 gauge panels and 60" on center for 22 gauge panels. |
| |
Construction No. 255 |
Minimum 24 gauge panels, 18" maximum width. 16 gauge purlins spaced 48" on center for all panel gauges. |
| |
Construction No. 261 |
10" wide panels only. 0.032 aluminum or minimum 24 gauge steel. 16 gauge purlins spaced 36" on center for 0.036 aluminum, 48" on center for 24 gauge steel or 60" on center for 22 gauge steel. |
| |
Construction No. 445 |
Minimum 24 gauge panels, 12" maximum width. 16 gauge purlins spaced 48" on center for 24 gauge panels and 60" on center for 22 gauge panels. 3" vinyl insulation is available. |
| |
Construction No. 446 |
Minimum 24 gauge panels, 18" maximum width. 16 gauge purlins spaced 48" on center. 3" vinyl insulation is available. |
| |
Construction No. 543 |
Minimum 24 gauge panels. 18" maximum width. 16 gauge purlins spaced 48" on center for 24 gauge panels (all widths) and 60" on center for 22 gauge panels (12" wide only). 3" vinyl insulation is available. |
| |
Construction No. 544 |
Minimum 24 gauge panels, 18" maximum width. Rigid insulation, plywood of OSB, gypsum board and 29 gauge liner panel are available. 16 gauge purlins are spaced 48" on center. |
| |
Over Wood Deck |
| |
Construction No. 343 |
Minimum 24 gauge panels, 18" maximum width. 5/8" plywood decking required. |
| |
Construction No. 414 |
Minimum 24 gauge panels, 18" maximum width. 5/8" Plywood decking required. |
| |
Construction No. 436 |
Minimum 24 gauge panels, 18" maximum width, 5/8" plywood or OSB decking required. |
| |
| |
|
| |