MBCI PRODUCTS

MBCI’s wide array of products is the most extensive in the industry. We offer single skin panels, insulated metal panels, retrofit solutions and much more.

 
     

-FICIENT® Insulated Fire Resistant Panel

The Insulated Fire Resistant Panel consists of metal facings bonded to a structural mineral wool core to create a composite panel that achieves fire resistance ratings under the most demanding of conditions. Unlike traditional wall materials, the Insulated Fire Resistant Panel offers a level of flexibility architects, contractors and building owners won't find in any other product in the U.S. The mineral wool panel is rated for its 1-, 2- and 3-hour fire resistance qualities and provides satisfactory thermal performance and protection from the elements. The R-value of this panel is 3.61 per inch of insulation.

-FICIENT® Insulated Fire Resistant Panel
  • Coverage Width – 42"
  • Thicknesses – 4", 5", 6", 7", 8"
  • Lengths – Recommended maximum is 40' Panel
  • Panel Attachment – Flush, double tongue-and-groove connection of the metal faces with an advanced integral spine to join the mineral wool core
  • Exterior Gauge – 26, 24
  • Interior Gauge – 26, 24
-----------------------------------------------------------------------------------------------------------------------------------------------------
Panel Profiles
 
-----------------------------------------------------------------------------------------------------------------------------------------------------
Additional Information
 
 
CAD Details Product Catalog Color Charts Warranties Photo Gallery Installation Manual
 
eco-FICIENT Spec Sheets CSI Specs      
Information Request Data Sheet CSI Specifications Brochure      
  -------------------------------------------------------------------------------------------------------------------------------------------------
Code Compliance
  Dade County Approvals
  NOA# 14-0306.03
  -------------------------------------------------------------------------------------------------------------------------------------------------
Fire Resistance Approvals
  Intertek – Wall & Ceiling Panel Fire Resistance Ratings
(ASTM E 119 & CAN/ULC S101)
Design No. Rating Panel Thickness
MS/WA 60-1 1 hr. Wall 4″
MS/WA 120-1 2 hr. Wall 6″
FC200 1-½ hr. Ceiling 6″
MSN/IMWP 180-01 3hr. Wall 8″

UL & ULC - Wall Panel Fire Resistance Ratings
(UL 263 approved for US & Canada)
Design No. Rating Panel Thickness
U050 (US)
W021 (Canada)
1 hr. Wall 4″
U050 (US)
WO21 (Canada)
2 hr. Wall 7″
U050 (US)
WO21 (Canada)
3 hr. Wall 8″
U054 (US)
WO22 (Canada)
1 hr. Wall
TS/CF Assembly
4″
U054 (US)
WO22 (Canada)
2 hr. Wall
TS/CF Assembly
7″
U054 (US)
WO22 (Canada)
3 hr. Wall
TS/CF Assembly
8″
 
UL – Fire Door Assemblies & Window Assemblies Fire Resistance Ratings
(UL 10B & UL 10C approved for US & Canada) 
Assembly No. Rating Panel Thickness
SP-2-001 1 hr. Door 4″
SP-2-001 1-½ hr. Door 7″
WA-2-001 1 hr. Window 4″
WA-2-001 1-½ hr. Window 7″

UL- ThermalSafe® Penetration Fire Stop Systems
(UL 1479 approved for US & Canada)
Penetrant Max. Size Insulation Fire Stop “F” Rating “T” Rating UL System
Steel Pipe
Iron Pipe
Steel Conduit
Copper Pipe
Copper Tubing
18″ dia.
18″ dia.
6″ dia.
6″ dia.
6″ dia.
N/A Cover Plate 1 hr. & 2 hr. 0 hr. & 1/4 hr. W-N-1001
Intumescent Caulk 1 hr. & 2 hr. 0 hr. & 1/4 hr. W-N-1002
Steel Pipe
Iron Pipe
Steel Conduit
Copper Pipe
Copper Tubing
8″ dia.
8″ dia.
6″ dia.
6″ dia.
6″ dia.
2″ Fiberglass Discontinuous Cover Plate 1 hr. & 2 hr. 1 hr. & 2 hr. W-N-5003
Intumescent Caulk 1 hr. & 2 hr. 1 hr. & 2 hr. W-N-5005
2″ Fiberglass Continuous Intumescent Wrap Collar 1 hr. & 2 hr. 1 hr. & 2 hr. W-N-5001
1″ Armaflex Continuous Intumescent Wrap Collar 1 hr. & 2 hr. 0 hr. & 3/4 hr. W-N-5004
PVS pipe
CPVC pipe
ABS pipe
FRPP pipe
6″ dia.
6″ dia
6″ dia.
4″ dia.
N/A Intumescent Wrap Collar 1 hr. & 2 hr. 1 hr. & 2 hr. W-N-2001
PVC pipe
CPVC pipe
6″ dia.
6″ dia
1″ Fiberglass Continuous Intumescent Wrap Collar 1 hr. & 2 hr. 1 hr. & 2 hr. W-N-5002
Steel Duct 23 1/2″ x 23 1/2″ & 23 1/2″ dia. N/A Retaining Angles & Intumescent Caulk 1 hr. & 2 hr. 0 hr.&
0 hr.
W-N-7001

Note:
  • The “T” and “R” ratings are for 4″ & 7″ thick wall panels respectively.
  • Continuous insulation extends through the wall opening. Discontinuous insulation does not extend through the wall opening, but
    terminates against the wall face on both sides.
  • Reference the UL Fire Resistance Directory for specific system details and materials.
  •   -------------------------------------------------------------------------------------------------------------------------------------------------
     
      TERMS | PRIVACY | CAREERS | SITE MAP | 877.713.6224