Designer™ Series

The Designer™ Series panels provide the toughness of metal while creating an attractive, flexible and functional wall or fascia panel. The Designer™ Series is offered in fluted and flat panels, which are equally effective for new construction or retrofitting existing buildings.

If your design calls for a smooth or flat wall or fascia, look to the Designer™ Series 12.0 Flat Panel. The Designer™ Series 12.0 Flat Panel offers a 1 ¾-inch deep leg providing the perfect cavity for rigid board insulation.

The Designer™ Series 16.0 Fluted Panel offers a continuous rib design with a hidden sidelap where the panels join together. Ribs are 4-inches wide and 3/8-inches deep, providing interesting shadow lines along the length of the wall. The panel legs are 1 ¾-inch deep allowing ample space for rigid board, blanket or batt insulation in the cavity.

Each panel features concealed fastened systems enhancing the appearance. One leg of the panel is attached to the structural using a concealed clip and the other leg snaps securely into the adjoining panel to lock them into position.

  Designer™ Series Product Information
  • Coverage Width – 12” (Flat Panel); 16” (Fluted Panel)
  • Panel Attachment – Concealed Fastening System
  • Finishes – Smooth (standard); Embossed (optional)
  • Coatings – Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
-----------------------------------------------------------------------------------------------------------------------------------------------------
Panel Profiles
-----------------------------------------------------------------------------------------------------------------------------------------------------
Additional Information
 
       
CAD Details Product Catalog Installation Manual Color Charts        
CSI Specs        
Warranties Photo Gallery Information Request CSI Specifications        
  -------------------------------------------------------------------------------------------------------------------------------------------------
Engineering Information
  Panel Section Properties: 12" , 16"
  -------------------------------------------------------------------------------------------------------------------------------------------------
Code Compliance
  ASTM E 1592 - Negative Uplift Testing:
12"   16"  
12" Designer TM 22 Ga. - load table   16" Designer TM 22 Ga. - load table  
12" Designer TM 24 Ga. - load table   16" Designer TM 24 Ga. - load table  
       
  -------------------------------------------------------------------------------------------------------------------------------------------------
  Florida Approvals
  FL 11917.1 12" Flat Designer Series over open framing
  Limits of Use
  Approved for use in HVHZ: No
  Approved for use outside HVHZ: Yes
  Impact Resistant: N/A
  Design Pressure: +45.00/-110.00
  Other: -110.00 psf @ 2'-0" o.c., -30.00 psf/+45.00 psf @ 8'-0" o.c. The panel is a concealed fastener wall system installed over open framing in accordance with the specified test pressuress. Limitations Non-HVHZ. Wall panels must be installed per manufacturer erection details.
Installation Instructions
FL11917_R0_II_12 flat designer manual.pdf
 
Evaluation Reports
FL11917_R0_AE_12 Flat Designer Series.pdf


     
  FL 11917.2   16" Fluted Designer Series over open framing
  Limits of Use
  Approved for use in HVHZ: No
  Approved for use outside HVHZ: Yes
  Impact Resistant: N/A
  Design Pressure: +30.00/-85.00
  Other: -85.00 psf @ 2'-0" o.c., -17.50 psf/+30.00 psf @ 8'-0" o.c. The panel is a concealed fastener wall system installed over open framing in accordance with the specified test pressuress. Limitations Non-HVHZ. Wall panels must be installed per manufacturer erection details.
Installation Instructions
FL11917_R0_II_16 fluted designer manual.pdf
 
Evaluation Reports
FL11917_R0_AE_16 Fluted Designer Series PER.pdf
 
   
 
  TERMS | PRIVACY | CAREERS | SITE MAP | 877.713.6224