Curved BattenLok®

When your roof calls for a curved standing seam metal roof, Curved BattenLok® is an ideal choice. The Curved BattenLok® profile is a water shedding, curved standing seam metal roof system with a 2-inch tall standing seam that is field-seamed during the installation process. Striations are standard and added for aesthetic value.

Curved BattenLok® may be curved to a minimum radius of 20 feet. Curved BattenLok® is a structural roofing panel and may be installed directly over purlins or joists. This curved standing seam metal roof system also may be installed over wood decks and metal decks with rigid insulation. Open framing applications eliminate costly curved deck surfaces and membrane underlayments. For large projects and/or long panels, the curving process for the curved standing seam metal roof system may best be accomplished at the job site.

Curved BattenLok® Product Information
  • Coverage Width – 16”
  • Panel Attachment – Concealed Fastening System; Low, High (fixed or floating), Utility (no insulation clearance)
  • Gauge – 24 (standard)
  • Finishes – Smooth Striated (standard)
  • Coatings – Galvalume Plus®, Signature® 200, Signature® 300
-----------------------------------------------------------------------------------------------------------------------------------------------------
Panel Profiles
 
-----------------------------------------------------------------------------------------------------------------------------------------------------
Additional Information
 
       
CAD Details Product Catalog Installation Manual Color Charts        
CSI Specs        
Warranties Photo Gallery Information Request CSI Specifications        
  -------------------------------------------------------------------------------------------------------------------------------------------------
Engineering Information
  Panel Section Properties: Please inquire with a sales person.
  -------------------------------------------------------------------------------------------------------------------------------------------------
Code Compliance
  -------------------------------------------------------------------------------------------------------------------------------------------------
  ASTM E 1592 - Negative Uplift Testing:
16"      
16" Curved BattenLok® 22 Ga. - load table   16" Curved BattenLok® 24 Ga. - load table  
  -------------------------------------------------------------------------------------------------------------------------------------------------
 

ASTM E 1646 & 1680 - Air & Water Testing

  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 580 Construction Numbers
  Over Metal Deck w/ Rigid Insulation
  Construction No. 577 24 gauge metal deck is required. Rigid insulation, plywood or OSB and gypsum wallboard are optional.
  Over Purlins & Joists
  Construction No. 583 24 gauge panels. Blanket insulation up to 6" thick is optional.
  Over Wood Deck
  Construction No. 576 24 gauge panels. 5/8" plywood or OSB is required.
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 790 - External Fire
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 263 Internal Fire
  Roof Assemblies  
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 2218 - Impact Resistance
   
 