Product Bulletins |
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
|
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
ASTM E 1592 - Negative Uplift Testing:
|
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
UL 580 Construction Numbers
| |
Over Metal Deck |
| |
Construction No. 310 |
Minimum 24 gauge steel or 0.032 aluminum panels. 16 1/2" maximum width. 22 gauge metal deck is required. 1/2" plywood or OSB, rigid insulation and gypsum board are available. |
| |
Over Wood Deck |
| |
Construction No. 280 |
Minimum 24 gauge steel or 0.032 aluminum panels, 16 1/2" maximum width. 5/8" plywood or OSB is required. 3" vinyl insulation is available. |
|
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
UL 790 - External Fire |
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
UL 263 Internal Fire
|
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
UL 2218 - Impact Resistance |
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
Dade County Approvals
|
| |
------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
Florida Approvals
| |
FL 11903.3 |
|
Craftsman SB over Plywood |
| |
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +n/a/-138.50
Other: 16.5" Craftsman -80.00 psf @2'-0" o.c., 12" Craftsman -138.50 psf @ 0'-6" o.c., - 54.25 psf @ 2'-0" o.c. The panel is a snap-on roof panel installed over open min. 19/32" plywood in accordance with the specified NOA #08-0412.11. Roof panels must be installed per manufacturer erection details. |
Installation Instructions
FL11903_R0_II_craftsman sb manual.pdf
Evaluation Reports
FL11903_R0_AE_craftsman SB1 PER.pdf
|
|