Craftsman™

The Craftsman™ Series is a snap-on batten roof system, available in narrow, wide and high profiles: small (SB), large (LB) and high batten (HB). The pan and batten are manufactured separately to maximize design flexibility and for ease of installation at difficult hip, valley and slope change conditions.

The Craftsman™ Series is a water-shedding system and can be used for roofs and mansard only when installed over a water-proofed solid substructure with a minimum roof slope of 3:12. The Craftsman™ Series design makes complicated building transitions simple without the necessity of flashings. Slope changes from roof to fascia to soffit can be made with one continuous pan and batten. A concealed clip securely locks the batten to the panel while allowing for expansion and contraction.

  Craftsman Series Product Information
  • Coverage Width – 12”,16 ½”
  • Minimum Slope – 3:12
  • Panel Attachment – Concealed Fastening System
  • Gauge – 24 (standard); 22, 26 (optional)
  • Finishes – Smooth (standard); Embossed (optional)
  • Coatings – Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
-----------------------------------------------------------------------------------------------------------------------------------------------------
Panel Profiles
-----------------------------------------------------------------------------------------------------------------------------------------------------
Additional Information
 
       
CAD Details Product Catalog Installation Manual Color Charts        
CSI Specs        
Warranties Photo Gallery Information Request CSI Specifications        
  -------------------------------------------------------------------------------------------------------------------------------------------------
Engineering Information
  -------------------------------------------------------------------------------------------------------------------------------------------------
Code Compliance
  -------------------------------------------------------------------------------------------------------------------------------------------------
  ASTM E 1592 - Negative Uplift Testing:
12" High Batten   16.5" High Batten  
12" CraftsmanTM HB 22 Ga. - load table   16.5" CraftsmanTM HB 22 Ga. - load table  
12" CraftsmanTM HB 24 Ga. - load table   16.5" CraftsmanTM HB 24 Ga. - load table  
12" CraftsmanTM HB 26 Ga. - load table      
12" Small Batten   16.5" Small Batten  
12" CraftsmanTM SB 22 Ga. - load table   16.5" CraftsmanTM SB 22 Ga. - load table  
12" CraftsmanTM SB 24 Ga. - load table   16.5" CraftsmanTM SB 24 Ga. - load table  
12" CraftsmanTM SB 26 Ga. - load table      
12" Large Batten   16.5" Large Batten  
12" CraftsmanTM LB 22 Ga. - load table   16.5" CraftsmanTM LB 22 Ga. - load table  
12" CraftsmanTM LB 24 Ga. - load table   16.5" CraftsmanTM LB 24 Ga. - load table  
12" CraftsmanTM LB 26 Ga. - load table      
  -------------------------------------------------------------------------------------------------------------------------------------------------
 

ASTM E 1646 & 1680 - Air & Water Test

  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 580 Construction Numbers
  High Batten
  Over Metal Deck
  Construction No. 309 Minimum 24 gauge panels, 16 1/2" maximum width, 22 gauge metal deck is required. Rigid insulation, plywood or OSB and gypsum board are available.
  Over Wood Deck
  Construction No. 282 Minimum 24 gauge panels, 16 1/2" maximum width. 5/8" plywood or OSB is required. 3" vinyl insulation is available.
  Small Batten
  Over Metal Deck
  Construction No. 310 Minimum 24 gauge steel or 0.032 aluminum panels. 16 1/2" maximum width. 22 gauge metal deck is required. 1/2" plywood or OSB, rigid insulation and gypsum board are available.
  Over Wood Deck
  Construction No. 280 Minimum 24 gauge steel or 0.032 aluminum panels, 16 1/2" maximum width. 5/8" plywood or OSB is required. 3" vinyl insulation is available.
  Large Batten
  Over Metal Deck
  Construction No. 308 Minimum 24 gauge panels, 16 1/2" maximum width. 22 gauge metal deck is required. Plywood or OSB, rigid insulation and gypsum board are available.
  Over Wood Deck
  Construction No. 281 Minimum 24 gauge panels, 16 1/2" maximum width. 5/8" plywood or OSB is required. 3" vinyl insulation is available.
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 790 - External Fire
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 263 Internal Fire
  Roof Assemblies  
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 2218 - Impact Resistance
  -------------------------------------------------------------------------------------------------------------------------------------------------
  Dade County Approvals
  NOA # 08.0402.11 (Small Batten Only)
  -------------------------------------------------------------------------------------------------------------------------------------------------
  Florida Approvals
  FL 11903.2 Craftsman LB and HB over Plywood
  Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +n/a/-52.5
Other: Craftsman LB and HB -52.5 psf @ 2'-0" o.c. The panel is a snap-on roof panel installed over min. 19/32" plywood in accordance with the specified UL Construction #281 (LB), and #282 (HB). Roof panels must be installed per manufacturer erection details.
Installation Instructions
FL11903_R0_II_Craftsman lbhb manual.pdf

Evaluation Reports
FL11903_R0_AE_Craftsman LBHB2 PER.pdf

  FL 11903.3 Craftsman SB over Plywood
  Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +n/a/-138.50
Other: 16.5" Craftsman -80.00 psf @2'-0" o.c., 12" Craftsman -138.50 psf @ 0'-6" o.c., - 54.25 psf @ 2'-0" o.c. The panel is a snap-on roof panel installed over open min. 19/32" plywood in accordance with the specified NOA #08-0412.11. Roof panels must be installed per manufacturer erection details.