7.2 Panel

When your design calls for a commercial or industrial exposed fastener panel, the 7.2 Panel is an ideal choice. This panel offers versatility and functionality for roofs and walls. The symmetrical rib 7.2 Panel offers excellent spanning and cantilever capabilities, making it an excellent choice for carports and walkway canopies

7.2 Panel Product Information
  • Coverage Width – 36”
  • Rib Spacing – 7.2” on center
  • Rib Height – 1-1/2”
  • Minimum Slope – ½:12
  • Panel Attachment – Exposed Fastening System
  • Gauge – 24 (standard); 29, 26, 22 (optional)
  • Finishes – Smooth (standard); Embossed (optional)
  • Coatings – Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
-----------------------------------------------------------------------------------------------------------------------------------------------------------
Panel Profiles
 
-----------------------------------------------------------------------------------------------------------------------------------------------------------
Additional Information
 
     
CAD Details Product Catalog Color Charts Warranties      
CSI Specs        
Photo Gallery Information Request CSI Specifications        
  -----------------------------------------------------------------------------------------------------------------------------------------------------------
Engineering Information
  Panel Section Properties: 36"
  -----------------------------------------------------------------------------------------------------------------------------------------------------------
Code Compliance
 

ASTM E 1646 & 1680 - Air & Water Test

  -----------------------------------------------------------------------------------------------------------------------------------------------------------
  UL 580 Construction Numbers
  Over Purlins & Joists
  Construction No. 244 Minimum 26 gauge panels. 16 gauge purlins spaced at 63 1/4". 4" Thick insulation is available.
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 790 - External Fire
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 263 Internal Fire
  Roof Assemblies Wall Assemblies
  -------------------------------------------------------------------------------------------------------------------------------------------------
  UL 2218 - Impact Resistance
  -------------------------------------------------------------------------------------------------------------------------------------------------
  Florida Approvals
  FL 11868.1 7.2 Panel over open framing
  Limits of Use
  Approved for use in HVHZ: No
  Approved for use outside HVHZ: Yes
  Impact Resistant: N/A
  Design Pressure: +n/a/-52.5
  Other: See Attached Section Properties and Allowable Load Table. The panel is a through fastened structural roof panel installed over open framing in accordance with the specified load tables. Limitations Non-HVHZ. Roof panels must be installed per manufacturer erection details.